TIA-568 and ISO 11801 Cabling Compliance.

Compliance with TIA-568 and ISO 11801 standards

Part of Structured Cabling. Last reviewed October 2026.

Quick answer

What is TIA-568 and ISO 11801 Cabling Compliance?

TIA-568 and ISO/IEC 11801 are the cabling standards used in North America and internationally, defining topology, link limits, component performance, and test methods. Deploris applies the standard that fits each site, selects the matching test limits, and delivers records that support your compliance evidence. Certification is a separate process by the standards body or manufacturer.

WHAT THE WORK COVERS

What TIA-568 and ISO 11801 Cabling Compliance includes.

  • 01Choosing the right standard per site, TIA-568 for US locations and ISO/IEC 11801 or EN 50173 for European locations
  • 02Hierarchical star topology with defined entrance facility, equipment room, telecommunications room, backbone, and horizontal cabling
  • 03Link and channel length limits, with 90 meter permanent link and 100 meter channel checked in the design
  • 04Test limit selection that matches the standard, for example Category 6A permanent link or Class EA permanent link
  • 05Pathway, administration, and bonding practices that follow TIA-569, TIA-606, and TIA-607 as the project requires
  • 06Fire and jacket rating checks against local rules, such as plenum or riser in the US and CPR classes in the EU
  • 07A written compliance statement of what was tested and to which standard edition

HOW WE DELIVER IT

How it is delivered.

  1. 1

    Identify applicable standards

    We list the standards that apply by country and building type, including any local code, landlord rule, or customer specification that is stricter than the baseline.

  2. 2

    Design to the standard

    Topology, cable categories, link limits, containment, and labelling are designed to the named standard edition. Deviations are listed and approved by you in writing.

  3. 3

    Install and test to the same limits

    Technicians install to the design and the tester is set to the matching limit, so results measure the right thing. A TIA limit is not interchangeable with an ISO limit in the tester.

  4. 4

    Package the evidence

    Test files, drawings, schedules, and a standards statement are assembled into one record that your auditor, insurer, or customer can review.

INPUTS AND OUTPUTS

What you provide and what you receive.

You provide

  • The standards or specification your organization, customer, or landlord requires
  • A list of sites by country, so we can apply the right regional standard and local rules
  • Any internal cabling policy, such as a minimum category or fiber type
  • Information on the audit or approval the evidence must support, if there is one

You receive

  • A standards statement naming the standard and edition applied per site
  • Test results using the matching limit, with the limit named in each file
  • A deviation list showing any approved departures from the standard
  • The drawings, schedule, and labels that complete the compliance evidence set

WHEN IT FITS

When this is the right deliverable.

Scenario 01

You operate offices in the US and Europe and need one cabling specification applied consistently with the right regional standard in each country.

Scenario 02

A customer, insurer, or auditor has asked for evidence that your cabling meets a named standard, not just a verbal assurance.

Scenario 03

You are replacing an old Cat5e plant and need to decide whether to build to Cat6A or Class EA for the next decade of Wi-Fi and PoE load.

WHERE WE DELIVER

Delivered in 75+ metros across 11 countries.

Local, vetted engineers deliver this work on site across the United States and Western Europe, coordinated by one engagement manager.

QUESTIONS

Frequently asked questions.

What is the difference between TIA-568 and ISO 11801?
TIA-568 is the North American standard family and uses categories such as Cat6A. ISO/IEC 11801 is the international standard and uses classes such as Class EA. They are closely aligned but not identical. Test limits differ, so a tester set to one standard does not prove compliance with the other.
Which cabling standard applies in Europe?
ISO/IEC 11801 is the international base standard. In Europe, EN 50173 is the closely related regional standard, and EN 50174 covers installation practice. Local fire regulations such as the Construction Products Regulation also govern cable jackets. We confirm which apply per country in the written scope.
Does Deploris certify that our cabling is compliant?
No. We install and test to the named standard and supply records that support your compliance evidence. Formal certification or a warranty is issued by a manufacturer or a recognized body, and legal code approval comes from the local authority. We do not claim approvals that belong to others.
Is Category 6A required by TIA-568?
TIA-568 recognizes several categories, and the standard does not force one choice for every site. Cat6A is widely recommended for new horizontal cabling because it supports 10GBASE-T to the full 100 meters and handles Wi-Fi uplinks and PoE well. The right choice depends on your applications and is set in the scope.

QUOTE

Request a quote.

Share a few details and we will come back with the next steps.

Get started

Need engineers on site? Tell us where.

Tell us the sites, the scope and the timeline. We reply with a written plan.

Go to

Saved and recent pages stay on this device. Press ? for keyboard shortcuts.

Keyboard shortcuts

Search the site
/ or Ctrl K
Show this list
?
Switch light, dark or system theme
t
Save or unsave this page
s
Go to the home page
g then h
Go to services
g then s
Go to coverage
g then c
Go to the contact form
g then q

Shortcuts are off while you type in a field.